<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15259</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: load ramp is tilted into drum no-fly zone
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The firmware thinks the load ramp is tilted in, towards the drum.
</text></DescriptionText>
<DescriptionText><text>
3230/3244 Trendsetter Autoloader: The "bottom out" sensor is reading FALSE.  The load
ramp sensors can be read with the "ramp" command.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Select Resume if that option is available.  If the problem persists, contact the Creo
Response Centre for assistance.
</text></DescriptionText>
</OperatorAction>
<Cause>
Faulty load ramp cylinders.
</Cause>
<Cause>
Damaged or misaligned load ramp sensor(s).
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_lrs.xml</LinkAddress><LinkTitle>NVS: al lrs</LinkTitle></Link>
<Link><LinkAddress>../commands/ramp.xml</LinkAddress><LinkTitle>Command: ramp</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:59 2008 PST
</Updated>
<Links>
</Links>
</Error>